一本色道DVD中文字幕蜜桃视频_夜夜高潮次次欢爽AⅤ女_色综合久久久久久久综合_狠狠色综合tv久久久久久

網站首頁技術中心 > 高低溫試驗箱風機盤管電機工作原理與燒毀故障分析

高低溫試驗箱風機盤管電機工作原理與燒毀故障分析

更新時間:2022-07-06 點擊量:983

                                高低溫試驗箱風機盤管電機工作原理與燒(shao)毀(hui)故障分析(xi)

高低(di)溫試驗箱風機(ji)(ji)盤管電(dian)機(ji)(ji)普(pu)遍(bian)采用單相運(yun)轉異步電(dian)動機(ji)(ji),且有高、中、低(di)等多檔調(diao)(diao)速,調(diao)(diao)速方法為(wei)副相抽頭的L型調(diao)(diao)速。電(dian)機(ji)(ji)的極數為(wei)四、六極。

  一、工作原理

  目前風(feng)機(ji)盤管電機(ji)普(pu)遍采用單相運轉異步電動(dong)機(ji),且有高、中(zhong)、低等多檔調速(su)(su),調速(su)(su)方法為(wei)副(fu)相抽頭的L型調速(su)(su)。電機(ji)的極(ji)數為(wei)四、六極(ji),接線電器原理(li)圖如(ru)下(xia):

  圖中的(de)M代表(biao)主(zhu)相(xiang)繞組(zu)(zu),A代表(biao)付相(xiang)繞組(zu)(zu),且副(fu)相(xiang)由a1、a2、a3三(san)層調速繞組(zu)(zu)串連(lian)而成,用(yong)以實現電機繞組(zu)(zu)帶負載(zai)時的(de)三(san)檔調速。

  二、接線錯誤(wu)導致(zhi)燒毀

  1:由(you)誤(wu)認零線和(he)多臺機組(zu)并聯使(shi)用導致。表(biao)現如下:

  燒毀原理:

  電(dian)機正常接線時(shi)電(dian)流圖,以低檔通電(dian)運行為(wei)例。

  接線錯誤將中檔接入外界零線時(shi)電流圖

  從以上示意圖可看出當(dang)低檔運行時起作(zuo)用的繞(rao)組(zu)是(shi) 1+ 2+ 3,而接線錯誤時,通電的繞(rao)組(zu)只是(shi)3,但(dan)這部分繞(rao)組(zu)阻值(zhi)很(hen)小,通電后造成電流過大,溫度(du)急劇升高(gao),且由于電機熱保護器(qi)是(shi)串聯于零線內,導致無法切斷電源,最(zui)終導致電機燒毀。

  注:以上圖為(wei)例,當機組一直運行于中(zhong)檔時,電機不會出現燒毀。

  主副相區分:

  主副相(xiang)區分時(shi),可將(jiang)副相(xiang)引線拉開,與(yu)其相(xiang)連的即為副相(xiang)繞組。

  高低溫試驗箱(xiang)風機盤管電機參考案例:

  1:某(mou)酒(jiu)店多臺(tai)電機燒毀,工程部將燒毀機組接線拆除。當天  檢(jian)查(cha)時(shi)又發生一臺(tai)燒毀,檢(jian)查(cha)接線如(ru)下:

  黃線為(wei)零線,現將高檔電(dian)源線接(jie)入機(ji)組零線。

  2:某酒店(dian)多臺電機燒毀(hui),現場發現電源線(xian)(xian)均(jun)使用同(tong)一顏色線(xian)(xian)。檢(jian)查發現電源線(xian)(xian)與零線(xian)(xian)混淆。如下:

  1、多臺(tai)機組并聯使用。

  同(tong)(tong)一只控(kong)制(zhi)開頭控(kong)制(zhi)兩臺及以上盤管機(ji)(ji)(ji)組(zu),即(ji)為多臺并聯接線。因電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)在(zai)(zai)高、中、低檔運行時,在(zai)(zai)副相繞(rao)組(zu)上,即(ji)紅、蘭、黑上會有(you)電(dian)(dian)(dian)(dian)勢(shi)(shi)存在(zai)(zai),不同(tong)(tong)電(dian)(dian)(dian)(dian)機(ji)(ji)(ji),對(dui)(dui)應顏色線上的電(dian)(dian)(dian)(dian)勢(shi)(shi)不同(tong)(tong),如強(qiang)制(zhi)并連在(zai)(zai)一起,就會有(you)電(dian)(dian)(dian)(dian)流從電(dian)(dian)(dian)(dian)勢(shi)(shi)高流入(ru)電(dian)(dian)(dian)(dian)勢(shi)(shi)低,在(zai)(zai)電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)與電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)之間形(xing)成環流,導致(zhi)電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)局(ju)(ju)部(bu)繞(rao)組(zu)溫升變高,嚴重時致(zhi)使電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)局(ju)(ju)部(bu)繞(rao)組(zu)燒毀,電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)停轉。此燒毀電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)對(dui)(dui)與之相對(dui)(dui)應之電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)局(ju)(ju)部(bu)繞(rao)組(zu)形(xing)成短路,很快(kuai)會導致(zhi)另一電(dian)(dian)(dian)(dian)機(ji)(ji)(ji)局(ju)(ju)部(bu)繞(rao)組(zu)燒毀。相同(tong)(tong)型號機(ji)(ji)(ji)組(zu)因風(feng)阻不同(tong)(tong)也會出(chu)現(xian)類(lei)似情況(kuang)。原理:

  2、整體高溫。

  以(yi)上(shang)情(qing)況(kuang)主要有以(yi)下因(yin)素(su)導(dao)致:

  A:電源異常(chang),如:電壓過高、頻(pin)率不對等;

  B:負載異常,如:風管(guan)、回風箱尺寸(cun)不符(fu)合要求,風輪改變(bian)等;

  C:堵轉,如:風(feng)輪卡(ka)死等。

  3、匝間燒毀。

  匝間短路主要是(shi)由(you)于漆膜(mo)破損(sun)導(dao)致的漆包線與漆包線之(zhi)間短路。

  導致匝(za)間短路的因(yin)素有:

  A:漆包(bao)線(xian)針孔(kong)多;

  B:定(ding)子繞(rao)嵌線時漆膜受(shou)損;

  C:使用時異(yi)物(wu)戳(chuo)入定子導致(zhi)漆包線受損。

  三、檢查流程

  出現電(dian)機不運行時,按以下步驟檢查:

  1:檢(jian)查(cha)控制器、電源是否正常(chang);

  2:檢查風管等外界因素(su)是否(fou)符合安裝要求;

  3:檢查電機電阻值和機組接線(xian)情況;

  4:檢查電機(ji)燒毀后定子情況(kuang),并根據以(yi)上參(can)照(zhao)進(jin)行(xing)判(pan)定。

  5:燒(shao)毀現象為副相(xiang)燒(shao)毀發黑,主相(xiang)正常的,應檢查(cha)機組接(jie)線,必 要時應全項目機組進行接(jie)線檢查(cha)。